kilowatts.io

My heat pump

6 kW R32 Mitsubishi Ecodan (PUZ-WM60VAA, FTC6). Water-side and refrigerant data read from the controller over CN105, electricity from a Shelly meter, every 30 s.

heatpumpmonitor.org →
Status
Off
no data
Electricity in
–W
Heat out
–W
COP now
–
Flow / return
–/–°C
Outdoor / room
–/–°C

Warnings

Suspect refrigerant behaviour detected automatically in the chart window: Fri 16 Oct, 09:32 – now

0 warnings0 cautions0 notes

Checking…

The system

Live readings sit where their sensors are.

Outdoor unitMitsubishi PUZ-WM60VAA · 6 kW · R32coilfan · air outcompressorplate heatexchangervalve Avalve Bpumpflow sensor3-way valveHouseradiatorsHot watercylinderController (FTC6)CN105 → Wi-Fi bridgeHome Assistant→ emoncmsOutdoor coil & fanCompressorPlate heat exchangerExpansion valvesPump, flow sensor & valveRadiators & houseHot water cylinderMonitoringOutdoor air –Discharge –Superheat –Fan –Compressor –Evaporating –Valve A –Flow –Return –Flow rate –Room –Tank –Electricity –
hot water outwater backhot refrigerant gasliquid refrigerantcold refrigerant gasmoving dashes = flowing nowTap a part to zoom in · tap a reading for what it means

History

Electricity – kWh
Heat – kWh
COP –

Fri 16 Oct, 09:32 – now

Download every variable for this window: CSV · JSON(30 s resolution up to ~3 days, coarser beyond; JSON includes each variable's description)

Power

The gap between the lines is free heat taken from the outdoor air

W

Water temperatures

Heating water leaving and returning, the cylinder, the house and outside

°C

Refrigerant temperatures

Discharge (orange) should sit well above the water flow temperature. When the two meet, liquid refrigerant is reaching the compressor

°C

Superheat & subcool

Superheat at 0 means the compressor is running wet: less heat for the same electricity

K

Expansion valves

How far open the valves feeding refrigerant to the outdoor coil are (480 = parked)

pulses

Compressor, fan & flow

How hard it is working

Hz · L/min · right axis rpm

Every variable, explained

Live values, with what each one means.

Power & efficiency

What goes in (electricity) and what comes out (heat). Heat divided by electricity is the COP: 3 means three units of heat for every unit of electricity.

Electricity in
–W

Electricity the whole heat pump is using right now, measured by a meter on its supply. About 20 W when idle.

Heat out
–W

Heat being delivered into the water right now, worked out from the water flow rate and how much warmer the water leaving is than the water coming back.

Electricity (total)
–kWh

Running total of electricity used since monitoring began. The period figure above the charts is the change over the selected time range.

Heat (total)
–kWh

Running total of heat delivered since monitoring began.

Water side

The heat pump warms water, which is pumped round the radiators or through a coil in the hot water cylinder.

Flow
–°C

Temperature of the water leaving the heat pump. Lower is more efficient: heat pumps work best making lukewarm water, not hot.

Return
–°C

Temperature of the water coming back after giving up heat in the radiators or cylinder.

Flow - return
–K

How much the water cools on its way round. Multiplied by the flow rate it gives the heat delivered. (K, kelvin, is just a temperature difference in °C.)

Flow target
–°C

The flow temperature the heat pump is aiming for. Set automatically from the weather and how warm the house is.

Flow rate
–L/min

Litres of water pumped through the heat pump each minute, from its built-in flow sensor. Zero when the pump is off.

Cylinder
–°C

Temperature of the hot water cylinder that feeds taps and showers. It is heated overnight on cheap electricity.

Room
–°C

Temperature at the room thermostat.

Outdoor
–°C

Outdoor air temperature at the heat pump. The colder it is, the more heat the house needs and the harder the heat pump works.

Refrigerant circuit

Inside the outdoor unit a refrigerant (R32) boils in the outdoor coil, picking up heat from the air even when it is cold, then is compressed so it gets hot enough to heat the water.

Discharge temperature
–°C

Temperature of the hot refrigerant gas leaving the compressor (sensor TH4). It should be well above the water temperature; if it drops to about the water temperature, liquid refrigerant is reaching the compressor.

Discharge superheat
–K

How far the gas leaving the compressor is above the temperature at which it turns back to liquid. Healthy is roughly 10–30 K. 0 means 0 or below: the gas is wet, which wastes energy and is hard on the compressor.

Subcool
–K

How far the liquid refrigerant has cooled below its condensing temperature after handing its heat to the water. A few degrees is typical. Negative readings are odd and may be a sensor quirk.

Evaporating temperature
–°C

Temperature of the refrigerant boiling in the outdoor coil (sensor TH3). It must be colder than the outdoor air for heat to flow in: typically 5–10 °C below it.

Two-phase pipe
–°C

A second refrigerant temperature in the outdoor unit (sensor TH6), where the refrigerant is part liquid, part gas.

Expansion valve A
–pulses

Opening of the main electronic expansion valve, which meters liquid refrigerant into the outdoor coil. More pulses means more open. It parks at 480 when the unit is off.

Expansion valve B
–pulses

A second expansion valve. On this unit it is set when a run starts and then mostly stays put.

Electronics temperature
–°C

Temperature of the heatsink on the inverter electronics that drive the compressor (sensor TH8).

Compressor & control

How hard the machine is working and what it has been asked to do.

Compressor speed
–Hz

How fast the compressor is running. Higher speed means more heat and more electricity. 0 means off.

Fan
–rpm

Speed of the outdoor fan that blows air across the coil.

Pump speed
–%

Water pump speed as reported by the controller.

Hot water mode
off

On when the heat pump is heating the hot water cylinder instead of the radiators.

Defrost
off

On while the outdoor coil is being defrosted. In cold, damp weather ice builds up on it and has to be melted off every so often.

Heating paused
off

On when the home automation has told the heat pump to stop heating, for example because the house is warm enough.

Wear

Lifetime counters. Frequent short runs wear a compressor more than a few long ones.

Compressor starts
–

Lifetime number of times the compressor has started. The controller only reports it in steps of 100.

Run hours
–h

Lifetime hours the compressor has run. Run hours divided by starts gives the average run length.